Objective:. Data comparing the outcomes of MiStent (Micell Technologies, Durham, North Carolina, USA) microcrystalline biodegradable polymer
Objective:. Data comparing the outcomes of MiStent (Micell Technologies, Durham, North Carolina, USA) microcrystalline biodegradable polymer (BP) drug-eluting stent (DES) and those of another post-marketing BP-DES, TIVOLI (EssenTech, Beijing, China) are rare. This study sought to compare the angiographic efficacy and clinical outcomes of the microcrystalline BP sirolimus-eluting stent (SES) system MiStent and those of TIVOLI BP-SES. Methods:. The DESSOLVE-C trial was a prospective, single-blinded, multicenter, randomized trial (NCT02448524), which randomly assigned patients with de novo coronary lesions to receive MiStent or TIVOLI BP-SES by a 1:1 ratio. The primary endpoint was a non-inferiority comparison of in-stent late lumen loss (LLL) by quantitative coronary angiography at 9 months. The secondary endpoint was device-related clinical cardiovascular composite events (target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (MI), and clinically driven target lesion revascularization) and 1-year outcomes. Results:. A total of 428 patients (216 patients in the MiStent group and 212 patients in the TIVOLI group) were enrolled and included in an intention-to-treat analysis. MiStent was not only non-inferior but superior to TIVOLI for in-stent LLL at 9 months ((0.23 ± 0.37) mm vs. (0.34 ± 0.48) mm, P for non-inferiority